Safety Relays
Category 4 Application
Emergency Stop & Gate Monitoring
SAFE 4
With Start Control Monitoring (Manual Reset)
Emergency Stop and Gate Monitoring
Applications
|
SAFE 4.1
Without Start Control Monitoring (Automaic Reset)
Emergency Stop and Gate Monitoring
Applications
|
| Part
Numbers |
SAFE
4 |
SAFE
4.1 |
| Operation Voltage |
24V AC/DC, 120V AC, 240 V AC |
24V AC/DC, 120V AC, 240 V AC |
| Output Contacts |
3 NO Safety, 1 NC Auxiliary |
3 NO Safety, 1 NC Auxiliary |
| Max. Contact Capacity |
5A (AC or DC) |
5A (AC or DC)) |
| Min. Contact Capacity |
1 mA |
1 mA |
| Switching Capacity |
1250 VA (Resistive Load) |
1250 VA (Resistive Load) |
| Power Consumption |
24VAC=5VA; 24VDC=3W; 120-230VAC=3.7VA |
24VAC=5VA; 24VDC=3W; 120-230VAC=3.7VA |
| Start Up Delay / Fallback |
<50ms / <30ms |
<50ms / <30ms |
| Simultaneity |
- |
- |
| Security |
6.3A quick acting or 4A time lag |
6.3A quick acting or 4A time lag |
| Temperature Range |
-25°C to +55°C |
-25°C to +55°C |
| Approvals |
CE, TUV, UL, cUL |
CE, TUV, UL, cUL |
Additional products are
available from the manufacturer. Please call us with your
application needs.
|