norstat navigator: non contact safety switches: F-Series Magneticallty Operated Safety System

Non Contact Safety Switches
F-Series Controllers and Extended Module
For Monitoring F-Series Switches

FM1 Controller Module FX1 Single Extender Module

All 'F' series systems start with the FM1. The FM1 contains the regulated power supply, 2 safety contact outputs, external/internal relay monitoring/reset circuit and system indication, along with the input for one safety switch sensor and it's indication outputs.
 
The FM 1 and one Safety Switch Sensor are all that is required for a system monitoring one guard. Simply connect
the FM1 into a suitable control input, fit the safety switch sensor to guard and connect the supply and the volt free control contacts as shown in the installation guide. For larger systems see FX1 & FX2 Extender units.

The FX1 is a 17.5mm wide extender module which clips onto 35mm DIN rail and connects to the main control module (FM1) via a 6 position ribbon cable.
 
The FX1 adds 1 gate switch input and corresponding LED and volt free contact indicator output.

FX2 Double Extender Module F-Series System

The FX2 is a 17.5mm wide extender module which clips onto 35mm DIN rail and connects to the main control module (FM1) via a 6-way connector strap.
 
The FX2 adds 2 gate switch inputs and corresponding LED and volt free contact indicator outputs.