norstat navigator: non contact safety switches: F-Series Magneticallty Operated Safety System

Non Contact Safety Switches
F-Series System Installation Drawings
Connection Diagrams

F-Series System Assembly
The FM1 control module monitors one gate switch. If no further gate switches are to be monitored, the CT1 (Terminator plug, supplied with the FM1) is fitted as shown. Where more than one safety switch is to be monitored, connect the required number of FX2’s and/or FX1’s to the main control module (FM1).  Fit the CT1 (Terminal plug, supplied with the FM1) to the last unit as shown.

F-Series Connection

The FX2 is a 17.5mm wide extender module which clips onto 35mm DIN rail and connects to the main control module (FM1) via a 6-way connector strap.
 
The FX2 adds 2 gate switch inputs and corresponding LED and volt free contact indicator outputs.