Safety Relays
Similar
Products
Category 4 Application
Additional
Information
Light Curtain Applications
SAFE L ‚ L.1
L - With Start Control Monitoring L.1 ‚ Without Start Control Monitoring
Monitoring Light Curtains or Other Safety Solid State Devices
|
SAFE L.2
With or Without Start Control Monitoring (Set by External Bridge)
Monitoring Light Curtains or Other Safety Solid State Devices
|
| Part
Numbers |
SAFE
L ‚ L.1 |
SAFE
L.2 |
| Operation Voltage |
24V AC/DC |
24V AC/DC |
| Output Contacts |
2 NO Safety |
3 NO Safety |
| Max. Contact Capacity |
6A (AC or DC) |
6A (AC or DC) |
| Min. Contact Capacity |
1 mA |
1 mA |
| Switching Capacity |
1500 VA (Resistive Load) |
1500 VA (Resistive Load) |
| Power Consumption |
3 VA |
3 VA |
| Start Up Delay / Fallback |
<50ms / <30ms |
<50ms / <25ms |
| Simultaneity |
40ms |
40ms |
| Security |
6.3A quick acting or 4A time lag |
6.3A quick acting or 4A time lag |
| Temperature Range |
-25°C to +55°C |
-25°C to +55°C |
| Approvals |
CE, TUV, UL, cUL |
CE, TUV, UL, cUL |